Flowline Liquid Level Control Selection Guide
Liquid level measurement, level control, and datalogging for automating tank systems
Choose the right liquid level products for your application:
1. Process Vessels
- Continuous level measurement
Cricket
Ricochet
Symprobe - High/low alarmsSwitch Pak
- Point level controlPoint level switches
2. Day Storage Tanks
- Continuous level measurement
Cricket
Symprobe - Fill between two pointsSmart Trak
3. Bulk Storage Tanks
- Continuous level measurementEchoTouch
- High level shut offSwitch Pak
- High level alarmSwitch Pro
4. Waste Sumps
- Empty between two pointsSmart Trak
5. Waste Storage Tanks
- High level shut offSwitch Pak
- Continuous level measurementEchoTouch
- High level alarmSwitch Pro
6. Waste treatment tanks
- High/low alarms in treatmentSmart Trak
- Caustic continuous level measurementEchoTouch
- Acid low level shut offSwitch Pak
Table scrolls horizontally
Media/tank conditions | Continuous Level Control | Point Level Control |
EchoTouch two-wire | EchoTouch three-wire | Ricochet | Cricket | Symprobe | Tuning fork switch | Ultrasonic switch | Buoyancy switch | SuperGuard RF capacitance | Non intrusive RF capacitance | |
| Foam | No | No | No | Yes | Yes | Yes | Yes | Yes | Yes | No |
| Bubbles | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Conductive | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Nonconductive | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | No | No |
| Clean | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Dirty | Yes | Yes | Yes | No | No | Yes | Yes | No | Yes | No |
| Noncoating | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Light coating | Yes | Yes | Yes | No | No | Yes | Yes | No | Yes | No |
| Medium coating | Yes | Yes | Yes | No | No | Yes | No | No | Yes | No |
| Heavy coating | Yes | Yes | Yes | No | No | No | No | No | No | No |
| Vapors | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Yes |
| Ambient pressure | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Low pressure | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes |
| Medium pressure | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Yes |
| Intrinsically safe | Option | No | No | No | No | No | No | No | No | No |
| Vacuum | No | No | No | No | Yes | Yes | No | Yes | Yes | Yes |
| Metallic tank | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | No |
| Nonmetallic tank | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Contact/noncontact | Noncontact | Noncontact | Noncontact | Contact | Contact | Contact | Contact | Contact | Contact | Noncontact |